x
earth

CUSTOMIZE YOUR EXPERIENCE

Close
Change Language: English Region: Americas

PowerCat 6 U/UTP 4 Pair Cable LS0H – Violet

'

Part No: CAA-00305, CAA-00325

Region: emea

Molex PowerCat 6 4 Pair U/UTP LS0H Cable has been designed to support high speed data transmission systems such as Gigabit Ethernet. The cable is part of the PowerCat 6 range of products that are designed to comply with the Category 6 specification. We recommend that the full range of PowerCat 6 products are used in a system to maximize cabling performance, providing extended frequency response and enhanced bandwidth.

Features & Benefits Technical Info Performance
  • Enhanced performance 4 pair LS0H cable
  • Category 6 compliant
  • Color coded for ease of termination
  • 500 meter and 305 meter reel
  • RoHS Compliant
  • Reaction to Fire Euroclass: Dca-s2,d2,a1

Mechanical Characteristics
Conductor Size: 23 AWG
Primary Insulation: HDPE
Sheath Type: LS0H
External O.D: 6.2mm +/-0.4mm
Sheath Color: Violet RAL4005
Average NVP% 69%
Maximum Pulling force 100N
Shipping weight: 305m box: 14.9kg

Fire Propagation Tests
EU Regulation 305/2011 (CPR)
EN 50575:2014+A:2016
Euroclass: Dca-s2,d2,a1
DoP No: MLXCES-2018-C-031 located on web http://www.molexces.co.uk/about-us/our-compliance/cpr/dop-certificates/

Commercial Standards
ISO/IEC 11801
EIA/TIA -568-C.2
EN 50173-1:2011
IEC 61156-5
IEC 60332-1-2 (332.1)
EN50288-5

PoE
Our PowerCat 6 system is suitable for PoE applications as defined below:
IEEE 802.3bt from Type 1 to Type 4, and CISCO UPoE+
Notes:
For new installations of PoE Type 3 / Class 5 and above that wish to be eligible for the Molex 25 year Application Assurance Warranty, we require Category 6A cable to be used throughout. To confirm your PoE / RP3 cabling design is eligible for the Molex 25 year Application Assurance Warranty, your design must be verified and validated with the Molex PoE Calculator. Read more at https://www.molexces.com/poe-calculator
Molex recommends that the PoE feature on an individual switch port is power disabled prior to unplugging the associated powered Device.
Molex recommends that the full range of PowerCat 6 products be used in a system to maximize cabling and PoE performance. Details on Molex requirements for Warranty can be found at: https://www.molexces.com/about-us/ourwarranty/

Electrical/Optical Characteristics
1.0-250.0MHz Impedance (Ω): 100±15
1.0-250.0MHz Delay Skew (ns/100m): ≤45
DC Resistance (Ω/100m) max.: 9.38
DC Conductor Resistance Unbalance (%): Maximum 5.0

For more information, refer to the datasheet for the Technical Performance (100m) table