Commercial Standards
ISO 11801:2017,
ANSI/TIA-568.2-D-2018
Fire Propagation Tests
IEC 60332-1
IEC 60754-2
IEC 61034-2
Mechanical
Conductor Size: 23 AWG
Primary Insulation: Polyethylene
Sheath Type: LS0H and PVC
External O.D: 6mm
Sheath Color: LS0H: White RAL9003; PVC: Grey RAL 7037
Average NVP%: 68%
Minimum bend radius: 4 x o.d.
Maximum Pulling force: 100N
Operating Temperature: -20° to 60°C
Installation Temperature: 0° to + 50°C
Electrical @ 20°C
Characteristic impedance @ 100MHz: 100±5 Ω
DC Conductor Resistance: 85 Ω/km
Insulation Resistance: ≥ 5 GΩ/km
Max. Resistance Unbalance: ≤2%
Max. Capacitance: 50 pF/m
Capacitance unbalance: 1600 pF/km
Propagation delay: 537ns/100m
Physical
Shipping weight: 10kg
PoE
Our PowerCat 6 system is suitable for PoE applications as defined below: IEEE 802.3bt from Type 1 to Type 4, and CISCO UPoE+
Notes:
For new installations of PoE Type 3 / Class 5 and above that wish to be eligible for the Molex 25 year Application Assurance Warranty, we require Category 6A cable to be used throughout.
To confirm your PoE / RP3 cabling design is eligible for the Molex 25 year Application Assurance Warranty, your design must be verified and validated with the Molex PoE Calculator. Read more https://www.molexces.com/poe-calculator
Molex recommends that the PoE feature on an individual switch port are power disabled prior to unplugging the associated powered Device. Molex recommends that the full range of PowerCat 6 products be used in a system to maximize cabling and PoE performance
Details on Molex requirements for Warranty can be found at https://www.molexces.com/about-us/our-warranty/