Commercial Standards
ISO/IEC 11801, EIA/TIA -568-C.2, EN 50173-1:2011, IEC 61156-5, IEC 60332-1-2 (332.1), EN50288-5
Fire Propagation Tests
EU Regulation 305/2011 (CPR)
EN 50575:2014+A:2016
EuroClass B2ca-s1a,d1,a1
DoP No: MLXCES-2025-C-026 located on web
molexces.com/about-us/our-compliance/cpr/dop-certificates/
RoHS COMPLIANT
Mechanical
Conductor Size: 23 AWG
Primary Insulation: HDPE
Jacket Type: LS0H
External O.D: 6.6±0.4 mm
Jacket Color: Yellow
Average NVP%: 69%
Maximum Pulling force: 110N
Electrical
1.0-250.0MHz Impedance (Ω): 100±15
1.0-250.0MHz Delay Skew (ns/100m): ≤45
DC Resistance (Ω/100m) max.: 9.38
DC Conductor Resistance Unbalance (%): Maximum 5.0
PoE
The PowerCat 6 system is suitable for PoE applications as defined below:
IEEE 802.3bt from Type 1 to Type 4, and CISCO UPoE+
Notes:
For new installations of PoE Type 3 / Class 5 and above that wish to be eligible for the Molex 25 year Application Assurance Warranty, we require Category 6A cable to be used throughout.
To confirm your PoE / RP3 cabling design is eligible for the Molex 25 year Application Assurance Warranty, your design must be verified and validated with the Molex PoE Calculator. Read more
https://www.molexces.com/poe-calculator
Molex recommends that the PoE feature on an individual switch port are power disabled prior to unplugging the associated powered Device.
Molex recommends that the full range of PowerCat 6 products be used in a system to maximize cabling and PoE performance
Details on Molex requirements for Warranty can be found at
https://www.molexces.com/about-us/our-warranty/