MECHANICAL
Conductor size [mm]: 23 AWG (0.570±0,005)
Insulated conductor diameter [mm]: 1.350 ±0,05
Color code: Blue x White/Orange x White/Green x White/Brown x White
Pair number: 4
Outside cable diameter [mm]: 7.4±0,5
Individual pair shield: Aluminium foil, providing 100% coverage, foil face out
Drain Wire: Yes
Overall shield: No
Temperature range [°C]
during installation: 0°C to +50°C
during operation: -20°C to +60°C
during storage: -20°C to +60°C
Acceptable bend radius
during installation: 8 x cable size
during operation: 4 x cable size
Pulling force: 100N max
Sheath: LS0H
Flame test: IEC 60332-1
Gas & smoke test: IEC 60754 (halogen & acid gas) and IEC 61034 (dense smoke)
Sheath color LSZH: Violet RAL4005
Shipping weight [kg]: 28.5
Cable length tolerance:+/- 5%
ELECTRICAL
Characteristic Impedance [Ohm]:
100±15 @ 1-250 MHz
100±20 @ 250-500 MHz
DC Resistance [Ohm/100m]: 9,38 max.
Resistance unbalance [%]: 2% max.
Capacitance [nF/100m]: ≤ 5.6
Voltage rating [Vdc]: 72 max.
NVP: 74% – printed on a jacket
Delay Skew [nS/100m]: ≤45
Insulation Resistance [MegaOhm•Km]: 5000 min. @ 500 Vdc
COMMERCIAL STANDARDS
TIA-568-C.2 for category 6A
ISO/IEC 11801 Ed.2.2: 2011
EN 50173:2011
IEC 60332-1 (single vertical cable)
IEC 60754 (halogen and acid materials)
IEC 61034 (no dense smoke)
RoHS compliant
FIRE PROPAGATION TESTS
Eu Regulation 305/2011 (CPR)
EN 50575:2014+A:2016
Euroclass B2ca -s1a d1 a1 class
DoP no MLXCES-2017-C-024 located on the web
APPLICATIONS
Category 6A U/FTP Cable is intended for high speed data applications up to 500 MHz including:
IEEE 802.3 10GBASE-T 10 Gb/s
IEEE 802.3 1000BASE-T 1 Gb/s
TIA/EIA-854 1000BASE-TX 1 Gb/s
ATM 155 Mb/s 155 Mb/s